Apply

Ready to go for it?

AI Apply speeds things up—apply directly if you prefer.

FREE ACCESS
5,000–10,000 jobs/day
Scoutfield Logo

See all jobs on Scoutfield

Search thousands of fresh jobs every day.

Discover
  • Fresh listings
  • Fast filters
  • No subscription required
Create a free account and start exploring right away.
Revamp Engineering, Inc.

Transmission Line Engineer II – High Voltage

Revamp Engineering, Inc.

. Design overhead gen-tie, transmission, and medium-voltage lines in PLS-CADD, including route evaluation, plan and profile development, structure spotting, sag-tension analysis, conductor selection, and clearance verification .

Posted 10/14/2026full-timeRemote • United StatesJuniorMid-Level💰 $99,800 - $144,700 per yearWebsite

Core Competencies

Role fit
Core Competencies

Use this summary to align your resume positioning with the role.

Demonstrates expertise in overhead transmission line design, including proficiency in PLS-CADD, PLS-POLE, and PLS-TOWER, while ensuring compliance with NESC and ASCE standards. Capable of managing project scopes, schedules, and budgets, while effectively communicating design progress and collaborating with multidisciplinary teams.

Highest-signal resume keywords
PLS-CADD ProficiencyOverhead Transmission Line Design ExperienceNESC Compliance KnowledgeEngineer in Training (EIT) CertificationFoundation Design Experience

ATS Keywords

Tailor your resume
Applicant Tracking System Keywords

Tip: use these terms in your resume and cover letter to boost ATS matches.

Hard Skills
Overhead Transmission Line DesignSag-Tension AnalysisStructure SpottingLoad Sheet PreparationFoundation DesignLiDAR Data ProcessingPlan and Profile DrawingsMaterial List PreparationSubstation Steel DesignClearance Verification
Soft Skills
Clear Written CommunicationVerbal CommunicationProblem SolvingTeam CollaborationMentoring
Tools & Technologies
PLS-CADDPLS-POLEPLS-TOWERAutoCADMicroStationPLS-CAISSONMFAD
Certifications & Qualifications
Engineer in Training (EIT)Professional Engineer (PE) License
Industry Keywords
NESCASCE 74ASCE 48Utility-Scale SolarGeneration InterconnectionsGeotechnical ReportsConstruction Drawing PackagesSubstation DesignTransmission Line ProjectsRight-of-Way Coordination

About the role

Key responsibilities & impact
  • Design overhead gen-tie, transmission, and medium-voltage lines in PLS-CADD, including route evaluation, plan and profile development, structure spotting, sag-tension analysis, conductor selection, and clearance verification
  • Model and check wood, steel, and concrete pole structures and lattice towers in PLS-POLE and PLS-TOWER under governing load cases
  • Prepare structure load sheets and specifications for custom steel poles, and review fabricator drawings
  • Develop insulator and hardware assemblies, framing details, and bills of material
  • Design or coordinate direct-embed and drilled pier foundations using geotechnical reports and foundation design software
  • Build terrain models and crossing data from LiDAR and survey files
  • Produce development, permitting, and issued-for-construction drawing and specification packages
  • Contribute to substation steel structure, bus support, and general arrangement deliverables
  • Adapt design methods to road, rail, and line crossings, constrained rights-of-way, and long spans
  • Lead small transmission line projects or defined portions of larger projects from kickoff through issued-for-construction
  • Manage design scopes to schedule and budget, and report progress and risks
  • Track RFIs, design changes, and scope changes; update deliverables when inputs change
  • Support construction by answering contractor questions, reviewing field changes, and preparing record drawings
  • Ensure designs meet NESC, ASCE 74, ASCE 48, IEEE, utility, and jurisdictional requirements
  • Follow QA/QC procedures, self-check models and calculations, and resolve review comments
  • Document design criteria, assumptions, and load cases
  • Coordinate with substation physical, protection and controls, civil, survey, geotechnical, and right-of-way teams
  • Attend project meetings and present design progress, issues, and recommendations
  • At Engineer III level, lead multiple projects, own scope/schedule/budget, solve complex problems, support client interaction, develop work plans, assign tasks, mentor junior staff, review deliverables, and act as Engineer of Record when licensed and assigned

Requirements

What you’ll need
  • Bachelor’s degree in Civil, Structural, Electrical, or Mechanical Engineering, or a closely related engineering field
  • Overhead transmission or distribution line design experience: typically 2+ years for Engineer II and 5+ years for Engineer III
  • Working proficiency in PLS-CADD, including sag-tension analysis, structure spotting, and clearance checks
  • Experience modeling structures in PLS-POLE or PLS-TOWER
  • Working knowledge of NESC, ASCE 74, and ASCE 48 as they apply to overhead line design
  • Experience preparing plan and profile drawings, structure load sheets, and material lists
  • Clear written and verbal communication, including documenting calculations for review
  • Engineer in Training (EIT) certification or Professional Engineer (PE) license preferred
  • Experience designing gen-tie lines for utility-scale solar, storage, or other generation interconnections preferred
  • Foundation design experience with PLS-CAISSON or MFAD preferred
  • Experience processing LiDAR data for line design preferred
  • Proficiency with AutoCAD or MicroStation preferred
  • Substation physical or substation steel design experience, or exposure to underground transmission design preferred

Benefits

Comp & perks
  • Participation in Revamp's Employee Ownership ESOP program
  • Competitive compensation with bonus
  • Full benefits package offerings including 99% employer-paid health, vision, life, and dental insurance
  • Medical, dependent care, and commuter FSA
  • Monthly health and wellness stipend
  • Attractive vacation, sick, and holiday pay
  • Paid parental leave
  • 401(k) savings plan with 100% match up to 6%, vested immediately
  • Paid volunteer time off and charitable donation matching